Rated operational voltage (Ue)
|
12 - 24 VAC (12 - 24 VCA) RMS incl. ripple 50-60 Hz, +15% tolerance 12 - 24 VDC (12 - 24 VCC) +15% tolerance |
|
No load supply current (Ie)
|
Typical Max. 192 mA 230 mA @ 12V AC 146 mA 170 mA @ 12V DC 103 mA 120 mA @ 24V AC 65 mA 80 mA @ 24V DC |
|
Technology
|
Digital video camera technology
|
|
Power ON delay
|
5 seconds
|
Output function Safety and Motion Zone |
Relay-SPST
|
|
Common relay data:
|
1A DC 30 VDC
|
|
Operations minimum
|
600,000 @0,5A, 50 VAC/30 VDC
|
|
Operations minimum
|
100,000 @ 1A, 30 VDC
|
|
Test Input
|
Max.input current 5mA
|
|
Active high
|
ON>9VAC/VDC OFF<6VAC/VDC |
|
Active low
|
ON < 6 VAC/VDC OFF > 9 VAC/VDC |
|
Sensitivity
|
Adjusting in 7 steps
|
|
Presence zone reaction time
|
|
|
Reaction time
|
210 ms (20% contrast, object speed 1 m/s, test body CA (DIN 18650-1)
|
|
Fall time
|
500 ms
|
|
Motion zone reaction time
|
|
|
Reaction time
|
1,2 s (20% contrast, object speed 1 m/s, test body CA (DIN18650-1)) |
|
Fall time
|
500 ms
|
|
Presence time
|
|
|
(Background relearn time ) In accordance with DIN 18650 Not in accordance with DIN 18650
|
7 step rotary switch 1 min, 5 min. 10 sec, 30 sec |
|
Vibration
|
10 to 150 Hz 0.5 mm/7.5g (IEC 60068-2-6)
|
|
Shock
|
2 x 1 m and 100 x 0.5 m (IEC 60068-2-32) |
|
Ambient temperature range
|
|
|
Operating
|
-25o to +55oC (-13o to +131oF)
|
|
Store
|
-25o to +80oC (-13o to +176oF)
|
|
Ambient light
|
10 lux-50,000 lux 40 lux-50,000 lux, TUV Approved, measured at the sensor surface
|
|
Contrast
|
Min. 20% contrast between the floor and object
|
|
Motion zone sensing area
|
(W x D)
|
|
Height 180 cm
|
246X204 cm
|
|
Height 220 cm
|
300X249 cm
|
|
Height 300 cm
|
410X340 cm The motion area can be blanked from left, right and front in 7 steps on three rotary switches |
|
Presence zone sensing area
|
(W x D)
|
|
Height 180 cm
|
42 cmx door width
|
|
Height 220 cm
|
51 cmx door width
|
|
Height 300 cm
|
70 cmx door width
|
|
Mounting height
|
1.8m to 3.0 m
|
|
Placement of sensor
|
|
|
Horizontal distance from door
|
Max 50 cm in front of the door. The sensor must be able to see the door opening.
|
|
Vertical distance from door
|
10cm from the top of the door opening
|
|
Material
|
|
|
Housing and cover
|
ABS Black
|
|
Front glass
|
Clear transparent, polycarbonate
|
|
Connection cable
|
3m8x0,14 mm2 LIYY grey max, cable length: 10m
|
|
Environmetal protection
|
IP64 (EN 60529, 60947-1)
|
|
Installation category
|
III (IEC 60664/60664A/EN 60947-1)
|
|
Pollutin degree
|
3 (IEC 60664 / 60664A / EN 60947-1) |
|
Humidity
|
0% to 90% relative, non condensing
|
|
Type of ESPE
|
|
|
Type 2
|
The sensing functions have to be tested for each door cycle by applying a test signal to terminals 2+3, see test input
|
|
LED indications
|
|
|
Green LED
|
Power On
|
|
Yellow LED
|
Motion detected
|
|
Red LED
|
Presence detected
|
|
Rated insulation voltage
|
50 VDC
|
|
Weight
|
460 g
|
|
Electromagnetic compatibility
|
In acc. with EMC directive 2004/108/EG Immunity in acc. with EN61326-1 and EN61326-3-1
|
|
Marking
|
CE
|
|
UL-Approval
|
UL325, CSA-C22.2 No. 24
|